Comportamiento de dos sistemas de postes prefabricados reconstruidos con resina sometidosa carga cíclica. Estudio piloto

Autores/as

  • Mauricio Naranjo Pizano Odontólogo CES Profesor de pregrado y postgrado Facultad de Odontología CES
  • Patricia Ortiz Perez Protesistas Periodontales CES
  • Clara Lucia Osorio Jaramillo Protesistas Periodontales CES
  • Jovan Ramiro Sepúlveda Ingeniero Mecánico EAFIT

Resumen

Una de las alternativas para la reconstrucción de dientes altamente destruidos son los postes prefabricados, elaborados con diferentes materiales, los cuales permiten la reconstrucción del muñón con resina, amalgama o ionómero de vidrio, para finalmente retener una corona que reproduzca la forma y la función. Esta investigación evaluó el comportamiento adhesivo de la resina de reconstrucción de muñón (Bis –core Bisco) con dos sistemas de postes prefabricados. Se utilizaron dos grupos de 10 especímenes cada uno (fibra de carbono y fibra de vidrio) con la respectiva reconstrucción de muñón en resina, sometidos a una carga cíclica de 98 newton, en una maquina de levas, simulando el ciclo masticatorio. No se encontró diferencia significativa en el comportamiento de cada tipo de poste con respecto a la resina. La resina falló en 4 de las 20 muestras, 3 de las cuales fueron cohesivas y una adhesiva. La falla predominó en el poste, ubicándose en la porción coronal de los postes de fibra de vidrio y más apical para los postes de fibra de carbono. Se concluyó que la interfase poste muñón es fuerte y que bajo carga cíclica la falla que se produce en los postes de fibra de carbono es más de tipo parcial y se ubica en el tercio medio; los postes de fibra de vidrio presentan una falla similar pero ubicada en el tercio cervical. Adicionalmente el tiempo promedio de duración de los sistemas fue de 4 a 6 años. ABSTRACT The prefabricated post are one of the alternatives to restore a very damaged teeth, those post are made of different kind of materials which allow the reconstruction of the core with materials as composite, amalgam and glass ionomer all this to create an ideal preparation to support a permanent fixed crown that will restore not only aesthetics but also function. The present investigation tested the adhesive behavior of one core composite material (Bis Core –Bisco) with two different kind of prefabricated post (Carbon fiber post and glass fiber post). They were ten specimens for each group and they were tested under cyclic load of 987NW in a Lavas machine simulating the masticatory cycle. There were not an statistically difference between the groups in relation of the core restoration but the core fail in 4 of the 20 specimens, 3 of them in a cohesive way, on the other side the more common failure was in the post, in the coronal third of the glass fiber and more apical on the carbon fiber. It was concluded that the adhesive interface between post and core is very solid and that under cyclic testing the failure for the carbon fiber post is more partial and in the middle third beside the glass fiber post which its failure is also partial but occur in the cervical third, additionally the average time of longevity under this circumstances was between 4 and 6 years.

Descargas

Los datos de descargas todavía no están disponibles.

Descargas

Cómo citar

1.
Pizano MN, Ortiz Perez P, Osorio Jaramillo CL, Sepúlveda JR. Comportamiento de dos sistemas de postes prefabricados reconstruidos con resina sometidosa carga cíclica. Estudio piloto. CES odontol. [Internet]. 1 de julio de 2009 [citado 17 de abril de 2024];17(1):31-8. Disponible en: https://revistas.ces.edu.co/index.php/odontologia/article/view/462

Número

Sección

Artículo de Investigación Científica y Tecnológica
Estadísticas de artículo
Vistas de resúmenes
Vistas de PDF
Descargas de PDF
Vistas de HTML
Otras vistas